The mini-refrigerators have become a promising choice for small homes and apartments, and for people who like to keep the refrigerator at arm’s length – it can be kept in the room.
Hisense has a promising range of mini-fridges available, and they are integrated with a small freezer to help you make a limited quantity of sugar for personal use. However, there have been complaints regarding Hisense mini fridge with freezer not cooling, but the cooling can be optimized by following the below-mentioned solutions.
Fixing Hisense Mini Fridge With Freezer Not Cooling
1. Evaporator Fan Motor
The first component that you need to check is the evaporator fan motor because it is responsible for producing and blowing cold air through the fridge’s evaporator coils to make sure it’s cooled down. When the fan motor stops working, the airflow over the coils will reduce, and the fridge will start overheating. There are various reasons behind a damaged evaporator fan motor, including a defective fan motor and a blocked motor.
There are chances that the motor is covered with frost, and you might not have mounted the fan motor properly – it happens when the compressor shaft is not connected to the motor. Last but not least, you have to check the connection between the fan motor and evaporator coil. If you have checked and fixed all these reasons, you can check the next solution.
2. Temperature Control Board
The second potential issue with the Hisense mini fridge is the damaged temperature control board. The temperature control board can get damaged with time, resulting in too low or too high a temperature. Keep in mind that the temperature control board has to be replaced because repairing is not possible. Also, always purchase the temperature control board according to the mini fridge’s model.
3. Compressor
A compressor remains the most important part of the fridge because it helps produce and retain cold air. When the compressor is blocked, it won’t be able to direct cold air into the fridge, which leads to cooling issues. The compressor is usually blocked when there is frost built up in the connections. So, check the compressor and make sure there is no ice buildup. You can hire an electrician to unclog the compressor because you might end up damaging the compressor unit.
4. Power Supply
Another thing you need to check is the power supply. This is because when the mini-fridge stops cooling properly, there could be chances of intermittent power connection. It is recommended that you check the power cord and make sure there are no damages – a damaged cord can lead to intermittent transmission of electric signals. So, get the power cords replaced by a professional electrician.
5. Defrost Heater
As the name suggests, the defrost heater is designed to produce heat within the fridge. It is basically a small heater that’s installed around the coils in a freezer section. So, when the defrost heater starts working too much, it will keep producing heat, resulting in cooling issues. In various cases, the problem is caused by a damaged defrost heater, so get it replaced and configured properly to optimize the heating intervals.